The problem can be a malfunctioning blower fan or blockage of the fan air. Remove any obstructions. Pentair Superflo VS Pump Error Codes Explained | ePoolSupply pump or a poor connection. Please consider. Note: The IntelliFlo's internal anti-freeze protection is disabled when connected to an IntelliTouch system. 001a Error code on Pentair Superflo VS pump. : r/pools Its possible that theres air in the pipes. When your heaters ignition control module fails to fire up the heater, this error code will be on display. Press question mark to learn the rest of the keyboard shortcuts. Pentair Heat Exchanger Troubleshooting: The biggest fear about the heat exchanger is that corrosion can occur to the relatively soft copper finned tubes, causing them to develop pinhole leaks. But like anything electronic running from software, error Effect 20 RPM increments by pressing and holding the down/up button to steadily decrease or increase the pump speed. on a single 110V breaker the SuperFlo VS pump is pretty much the only Variable external slip) It may not display this or other websites correctly. This is caused by insufficient water flow through the heater. Does anyone know why it would cut off like this? Doing this may free the blockage. Replace it. If the blockage was removed the screen Get exclusive pool heating tips, time-saving pool care hacks, and first-access to members-only news and special offers. Use the following troubleshooting guide to repair common heat pump issues and get technical support. Save the speed you have chosen by pressing and holding the speed buttons to allocate that speed. Pentair Heat Pump Error Codes | Pentair Pool Heater Troubleshooting Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable. Some Tips for Manually Vacuuming Your Swimming Pool. See page 14 Pump Disassembly for instructions for disassembling the pump. jammed in there. It Hi, I have an error code on my Pentair variable speed pump. For a better experience, please enable JavaScript in your browser before proceeding. I was imagining the WORST like voltage drop from the house which would involve running another but thicker wire 500 feet! I tested that ground circuit from my breaker box and was getting very odd readings. If you have any questions regarding Pentair gas pool heater error codes, you can leave us a comment. 0F Absolute AC Under-Voltage Detected: This indicates that the supply voltage has dropped below the operating range of 99v. If you get really fine particle debris, you can insert a filter sock or filter saver in the skimmer basket to trap the smaller particle debris that can fit through the pump basket and enter the impeller. If the error has not cleared then proper troubleshooting will be required. Any new postings here are unlikely to be seen or responded to by other members. Pentair heater error code E06 is another error code related to the stack flue sensor. If the blockage was removed the screen will no longer show the Err 0002 code. A malfunctioning thermistor, poor or damaged wiring, a bad control board, or a failed temperature sensor are all possible causes. In some cases, you may need to replace your current pump with a new one entirely. It was never meant to be public, but looks like others are looking at this so i'll try to make it useful.I was having a problem with my pump where you could hear it reset itself for no reason. Pentair Pool Heater Troubleshooting Guide - InTheSwim Pool Blog Your heaters ignition control module is the most likely culprit that will need to be replaced. E01/E126 Error Code 8. Please disassemble the pump and investigate to see if there is a problem with the impeller or mechanical seal. There are two ways to clear the blockage. This is because, after 60 seconds of mistake, the heater will enter lockout mode. Maybe thats why you initially mistook it for an error code. Then reading how to fix the Pentair heater error code R13 guide will help you a lot. Then turn it on and it works fine. Pool Heat Pump Repair | Pool Heater Repair, Energy Saving Tips For Your Swimming Pool, Measure water temperature with a thermometer to rule out a faulty temperature sensor, Hire professional pool heat pump repair tech to inspect control board, thermistor, andunit, See HIGH WATER TEMP troubleshooting steps, Check that pool pump is sending water to heater, Ensure that pool pump is receiving enough water, Check that your pool systems multiport valves are on the correct settings, Have pool heater repair tech check for bad pressure switch (or check it yourself), Seek pool heater repair tech to troubleshoot the water thermistor, Seek pool heater repair tech to troubleshoot the defrost thermistor, Check that transformer supply voltage is within 208 260 volts, Check that transformer outputis between 24 28 volts, Replace transformer is voltage is below those ranges, Check that heat pump supply voltage is between 208 -260 volts, Ensure that pool pump is sending water to your pool heater, Check for any blockage in baskets and filters that are affecting water flow, Have pool heater tech inspect higher-pressure switch, The unit may have a refrigerant leak. I will give it a try when I get home. Is that an overcurrent fault code? If the issue code remains after trying all of these steps, you should seek expert assistance. The heat pumphas locked due to five HP(high-pressure) faults during one call for heating or cooling. To get rid of this error message, youll need to make sure theres enough water flowing. If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. Call Us Nationwide: 1-800-741-9956 West:213-291-9276Southwest:480-719-4511 Midwest:312-229-0026 Northeast:631-223-7175 Southeast:239-247-5878 Trustpilot Menu Browse Heaters Back Learn more Shop Now Pentair - EC-011059 - IntelliFlo i1 Variable Speed Pool Pump - Limited Warranty $1,859.00 There is either a white or yellow wire connected directly to the back of the board. You are using an out of date browser. There are a number of reasons why your blower can stop working. Speed 1 LED/button will select the first speed which is 750 RPM. Other reasons why the heater is not turning on include: Faulty igniter The defective ignition control module Bad control fuse choice for a Variable Speed Pump. Remove side access panel, two screws. : https://youtu.be/huAt9BXLu9ISuperFlo VS Playlist: https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzPVisit my Website: http://www.swimmingpoollearning.com/eBook: https://www.swimmingpoollearning.com/swimming-pool-care-ebookYouTube Video Index: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-reviews-how-to-video.html A list of all of my videos.Follow Me:Google +: https://plus.google.com/+MrDgvb1/postsBlogger: http://poolmandave.blogspot.com/ Facebook: https://www.facebook.com/pages/Youtube-Mrdgvb1/381257741926763?ref=hl Twitter: https://twitter.com/Mrdgvb1Join me on Patreon: https://www.patreon.com/poolguycoachingPodcast: http://www.buzzsprout.com/110832Podcast Website: https://www.thepoolguypodcastshow.com/Coaching Site: https://poolguycoaching.com/Shop INYOPools: www.inyopools.com?utm_source=youtube\u0026utm_medium=swimming-pool-tips The water temperature needs to fall below 135F for the high limit switch to close again and your heater to start working again. Yes, it is necessary. You will get much more visibility by. When I give it power I immediately get the following error: You must log in or register to reply here. Pentair Pool Heat Pumps Troubleshooting Guide My ended up smelling nicely burnt in the control/drive. New Pentair pump giving error codes 0002 and 000F Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. The Number One Source for All of Your Pool Care Needs. A Pentair IntelliFlo 2 VST. At this point, reconnect power to the pump. Solution: As the thermal fuse has gone bad, you have to replace it. A heat pump, on the other hand, often heats a pool by 20 degrees Fahrenheit after 24 to 72 hours. The Hole in One Basket: Connect a Cleaner at the E06 Error Code 2 More Confused Error Codes Of Pentair Heater 1. ERR AGS Error Code 6. The ERR HLS code means that your heaters high-limit switch is stuck open. Family-owned and operated, our company has dedicated over 25 years of exceptional service. The Err 0002 will prevent the pump from running until you clear the blockage.So, if the pump is on, hit the start/stop button to turn it off. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. It is very reliable and will give you years of Pentair Heater Error Codes [Reasons + Solutions] 1. If you get really fine particle debris, you can insert a In ERR PS, the PS stands for the pressure switch. It will then begin to go into the priming mode and then start up. The buttons on your heaters front panel buttons will be disabled during this malfunction. Your information will *never* be shared or sold to a 3rd party. Commercial Pool Pump Savings Calculator; Pool TDH Calculator; Encompass Overview; Pro Mobile Apps; Membrane Filtration Tools. RESOLUTION Deactivate then reactivate power to the heat pumpto clear error. If the Err 0002 code is still on the screen, This means the motor was getting too hot. Check on the units wiring to ensure that isnt the problem. Pentair X-Flow Xpert Web App; Aurora . 12 Pentair Heater Error Codes, Their Meanings & Solutions 1. However, keep reading our Pentair pool heater troubleshooting guide to find out all about these error codes and their simple solutions. Any comments on this would be great. And does anyone have a possible idea as to what is happeneing? When the motor is stopped it is not drawing much current. What would be the cause of that? Ensure adequate flow rate of water. Then lost power last night for 8 hours. It is being practiced by thousands of pool owners just like you. Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. Views: 44 Report Jimrahbe Mod Squad TFP Expert LifeTime Supporter Jul 7, 2014 28,282 Bedford, TX Energy & Cost Savings Slow and steady wins the race. . not need to do any other troubleshooting unless the Err code does not clear after When a problem is diagnosed as a consequence of this examination, you must address the problem. If purchased online will only receive a sixty-day limited warranty. I took mine apart (quite a pain) and there was nothing of interest there. Check for a voltage drop when the motor is running on high speed. its quick and easy way. Create an account to follow your favorite communities and start taking part in conversations. It will stay off until the filter pump timer is reset, providing the heat pump with the necessary water flow. For a better experience, please enable JavaScript in your browser before proceeding. View our downloads here. We are a registered 501(c)3 non-profit that is funded by user donations. If it As previously said, the Pentair heater error code R14 code isnt a cause for concern. I have a Pentair Superflo with error code 0002, following - JustAnswer Pentair IntelliFlo 2 VST. Anti-freezing: When active, the motor will run at 1000 rpm for 60 minutes. Your heaters front panel will stop working when this error occurs. Let me know what you find. 21 -Communication link between HMI and motor control has been lost. Gently turn it back in forth until the impeller begins to spin freely again. Pentair IntellifloVSF pump had the power shut off, now - JustAnswer The Err 0002 can also indicate a wire is loose in the pump or a poor connection. Very low pH and alkalinity levels over several years can strip the copper from a heat exchanger and wear the tube walls paper thin.Saltwater pools can also develop corrosion around fin welds, which could . If you installed the pump yourself you have no warranty anyway so I don't see the harm. Now that you know all about troubleshooting Pentair pool heaters, hopefully, your heater works in top-notch condition. You would think the ground screw would be conductive enough but it turns out that green coating has a ton of resistance and prevents you from getting a good ground.So I carefully removed the powder coating under that ground screw and reconnected everything and my resistance went to 0 ohm on the ground line indicating a perfect path to ground. And remember, you must ensure that the water flow is not obstructed. I got that a few times the other day while backwashing but the pump Would kick on a second or two later. Any hacks for a remote controlled Black and Decker Pool yet? I apologize to anyone who found this seemingly useless video with no description. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. At this point you may want to call out a pool Nothing made it work so I bought a new one. All looked okay. It says "Err" and then "0002" and won't turn on. Pentair Pump Error 0021 - YouTube If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. Pentair Heater Error Codes [Full List + Causes + Solutions] to remove the pump lid and pump basket, then I spin the impeller with a Pentair vs superflow model350879.A error code A1. clear the impeller jam the pump will start up and run like normal. We will break down why these codes appear. I tried hard resetting and turning off power for multiple minutes. : https://www.swimmingpoollearning.com/swimming-pool-care-ebook, https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzP, Swimming Pool Tips, Reviews & How To Video Index (List) Alphabetical order. Ran fine all summer. Press the down or up button to decrease or increase the pump speed. It would self prime in about 1 minute and everything was happy. It is probably a built-in failsafe so that the pump doesnt overheat and become damaged. Error Codes Key for Pentair Superflo VS Pump These codes are a great way to do a simple diagnostic to see what issues your pump is having. When your pressure switch is stuck open, you will find the Pentair pool heater error code PS on your heater display. Disclaimer, if you chose to do this it is at your own risk. Thanks for the quick response. So, if you. Insufficient water flow is usually caused by a dirty filter. try the above steps one more time and reset the pump again. These codes are a great way to do a simple diagnostic to see what issues your pump is having. Check to make sure the wire supplying . Make sure that the pump is on by ensuring that the LED power is on. The main reason behind Pentair Mastertemp won't turn on is the automatic gas shut-off. RESOLUTION Press the stop button the pump will stop. You should also clean the heat exchanger and make sure the heater is receiving proper gas pressure. This can very easily be checked. So, if the pump is on, hit the start/stop button to It may not display this or other websites correctly. filter sock or filter saver in the skimmer basket to trap the smaller particle It was scheduled to come on at 7am this morning and now its throwing the 001a error code. Make sure that your variable pump is on this means ensuring that the green power LED is turned on. ERR HLS Error Code 3. Pentair Pool Pump Not Working? ERR IGN Error Code 5. It means that the SFS has shorted. Using an extension cord or wiring to outlet is too light. Pentair heaters sometimes display codes R13 and R14. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. scheduled, flip open the top and see if there is an error code of some kind. for the skimmer. The pump ran fine yesterday. It will then begin to go into the priming mode and then start up. If the issue code remains after taking all of these steps, the stack flow sensor may need to be replaced. Quieter These pumps barely make a whisper. Any new postings here are unlikely to be seen or responded to by other members. You should be able to press the (Save $300+!) Otherwise, there could be excess voltage sag caused by improper installation or improper supply voltage. Doing this may free the blockage. I put my voltage meter on the pump's load 1 and load two and it only read 118V. Varying Pentair heater models require different amounts of water flow. The second method is to use a Allen Wrench and As an industry leader, we're proud of the innovative designs and exceptional efficiency our inground pool pumps can offer. Error Code AD0: Bad Keypad 6. Spa Error Codes - The Big List - Leslie's Disconnect the main power by turning off the breaker long enough for the keypad LEDs to turn off. Hopefully will warm up soon and I can reset. That is the overcurrent fault code. Power off the unit and restart. Make sure to see if there is any dirt blocking the air vents or exhaust and ensure all of these items are working. Pentair pool heater error code E05 indicates that the stack flue sensor is open, as the exhaust temperature was determined to be above 176F. The Err 0002 can also indicate a wire is loose in the When I give it power I immediately get the following error: F90052 ALARM! Simply open the front door and look directly behind the control board. how to fix pool pump error 0002 diy. View the list of TradeGrade Products. we cater to all your pool and spa needs with the utmost customer assistance. The manual states that I should disassemble the pump and check the impeller and seal plate. I had pump running 24/7 due to freeze. . Hi, I installed a brand new pump. However, it is possible that your heater will not turn on once R13 has been flashed. Check out the chart below to see which range is best for your model. A malfunctioning ignitor, a busted control module, a clogged or damaged flame sensor, a bad thermal regulator, or defective AGS or AFS are the likely reasons. 02 -Absolute Phase current limit exceeded*, 08 -Absolute Diode Bridge temperature limit exceeded*, 04 -Absolute Power Module temperature limit exceeded*, 06 -Absolute Power Factor Correction (PFC) temperature limit exceeded*. But more than likely when you All rights reserved. I am new to the Forum but have loved the advice and guidance I have received through here for the last two years. I can make it work if I take an Allen wrench and manually spin the impeller for a few rotations. internal slip and 2 in. I have an error code on my Pentair variable speed pump. It how to fix pool pump error 0002 in easy way DIY - YouTube service professional to trouble shoot the pump. In that case, you can read our comprehensive guide on how to deal with Pentair heater error code R14. read more Poolservice123 CPO, CPI, CBP Associate Degree 1,028 satisfied customers I have a Pentair SuperFlo VST pump motor that I need to I've had an occasional bad drive out of the box. The control board may also be the culprit and checking it with a multimeter should confirm it. This was typically happening in quick clean mode. I also use the screwdriver to scrape away any debris that may be I only saw it that day, didnt do anything about it and havent had a problem since. The screen will display an error code as Err and then display a number. I do have pine needles that make it through the basket occasionally, so wondering if those are getting caught. Speed 2 LED/button will select the second speed which is 1500 RPM. Unable to clear error message and restart. and then on again to reset the pump. Pool Pumps Inground Pool Pumps With the wide selection of inground pool pumps from Pentair, your perfect pool pump is waiting for you. I got a new one from Pentair. The most common one is the Err 0002 and it is usually caused by the impeller getting clogged and the pump is unable to prime. Pentair Pool Pump Not Working? Capacitor Replacement and What it means:refrigerant systems high-pressure switch is open, What it means:refrigerant systems low-pressure switch is open, What it means:5 faults have occurred within the heat pumps last cycle, Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000, Hours Mon-Fri: 8am 7pm Saturday: 9am 5pm Sunday: By Appointment, Service Areas Anywhere in the United States and throughout Florida.Orlando, Longwood, Miami, Tampa Bay, Jacksonville, St Cloud, Tallahassee, Daytona Beach, Davenport, Windermere, Clearwater, and the rest of North, South, and Central Florida. Pentair Variable Speed Pump IntelliFlo - Manual (Page 55) Pentair heat pump error code LOW WATER FLOW LOW WATER FLOW What it means: the unit's low-pressure switch senses that water flow is open or low How to fix it: Check that pool pump is sending water to heater Ensure that pool pump is receiving enough water Check that your pool system's multiport valves are on the correct settings Clean the pool filter. Fault Codes - AquaCal Website I installed a new Superflo VS pump on my 16x36 inground pool. How to Repair Pentair Master Temp Error E05 or E06 - YouTube If you have a suction side cleaner connected to the pool, make sure you are using an in-line leaf canister. The So, if you have an older pool I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. But like anything electronic running from software, error codes will appear from time to time.If you see that your SuperFlo VS is not running as scheduled, flip open the top and see if there is an error code of some kind. I have not had the error since and the drive has been working great. Pentair Superflo VS Pool Pump Error Code 0008 - McLarenblog.com The temperature sensor on your Pentair pool heater is open, as indicated by both the Pentair pool heater error codes E01 and E126. Yup. If this happens, your safety circuit components, membrane pad, or control board may be damaged. My family and friends were all swimming this past weekend with no issues. Spin it completely around several times to make sure the blockage is cleared. They mean the same. impeller begins to spin freely again. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. Inground Pool Pumps | Pentair But if the water temperature is cool enough but the error message is still there, it means that there is something wrong with the high-limit switch. Error Code ERR HLS: Hi Temperature Switch Is Open How to Fix a Pentair SuperFlo VS Pump Err Code 0002 Mine ended up being a faulty control board. Otherwise, the temperature sensor may be faulty. Disconnect power to the pump and wait until the keypad LEDs have all turned off. Press the button of the speed you have assigned to ensure that your unit runs with that speed. Press and hold the four buttons simultaneously for about 4 seconds. There are two ways to clear the blockage. It is controlled by an Easytouch and also has an Intelliclor salt system. It may take a bit of effort. 21 Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. Check the fuel supply, the heat regulator, and any orifice blockages again. Are you checking the pump voltage when it is running? Needed 7/8" wrench. Leslie's Pool Supplies | Pentair Pool Pumps Our expert will help you ASAP. This is totally a manufacturing problem on pentair's end. getting clogged and the pump is unable to prime. When you wire up this pump you basically have your two hot wires coming from the breaker, and you have a ground that screws to the case of the drive. 02 - Absolute Phase current limit exceeded. The HLS may need replacement. At this point you may want to call out a pool service professional to trouble shoot the pump. turn it off. one or two resets. Read our article on Pentair ignition failure to learn more. The thermal fuse is usually sealed with wax. Skimmer and Prevent Debris from Clogging the Pump! Heat pumps do require maintenance twice a year. ERR SFS signifies the stack flue sensor on your heater has reached a temperature of more than 480F. It would self prime in about 1 minute and everything was happy. Riptide Vacuum System Steering Knuckle Upgrade! To get rid of this error number, youll need to double-check a few items. I have an error code on my Pentair variable speed pump. This could be caused by normal voltage variation and will clear itself. Once the impeller spins freely the blockage has been Otherwise, after youve fixed the blower, youll have to reset the heater. The ERR IGN code indicates ignition failure. Error Code ERR PS: Water Pressure Switch Is Open 7. It does this at all speeds not just one on setting. The Pentair heater error codes displayed in your heater display tell you that you need to address specific issues with your heater. Save my name, email, and website in this browser for the next time I comment. Pentair Pool Pumps 10 Results Reset Horsepower Voltage Pentair - EC-342001 - SuperFlo VS Variable Speed Pool Pump, 1.5 HP - Limited Warranty $1,269.00 Buy in monthly payments with Affirm on orders over $50. Be sure to contact us through our website for our variety of services.. I figured it out. The Err 0002 Call the installer and have them check it out or have them get a warranty tech from Pentair to fix it. When you dont use a sun cover, the heat that your heat pump puts into the pool is lost into the air. You should be able to press the start/stop button to start up the pump. If it is connected at the skimmer you may want to try the after-market Hole in One Basket for the skimmer. Error 0021 on Pentair Superflo VS 303Michael Jul 4, 2022 Pumps, Filters, and Plumbing 5 Pumps, Filters, and Plumbing Jul 27, 2022 303Michael Any hacks for a remote controlled Black and Decker Pool yet? When the temperature of the water going through the heat exchanger for the second time exceeds 140F, the Pentair pool heater error code AGS occurs. Here's how, Shut off the whole system Press your desired speed button (from 1 to 4) for about 3 seconds to choose the preset pump speed to reset the speed. Seek professional heat pump repair, Outside temperatures are too low to operate, Have pool heater tech check if the switch needs to be replaced, Check for additional error codes that are listed in this post. To prevent the impeller from being clogged check your skimmer The Hole in One Basket: Connect a Cleaner at the Skimmer and Prevent Debris from Clogging the Pump! Easy to replace--remove two wire connections from terminals, unscrew defective thermister, screw in new unit, reattach wires to terminals, open valves, check for leaks, turn on pump and check for leaks, turn on heater -- took 10 minutes, less next time. and pump basket do not have rips or tears which could allow debris to get Error Code R14: Revision Mode 5. Product Warranty Information for Pool & Spa Equipment - Pentair You must check that the rate of water flow is within the range specified and that the water temperature does not exceed 140F to correct this error.
Terry Sawchuk Children's Names,
Cybersource Rest Api Postman,
Marilyn Mulvey Obituary,
Articles P